Chris,

This subject does come up from time to time, and the most common cause for weak APP connectors is due to improper assembly. Look in the end of your APP connectors. If you can see the tip of the spring that is supposed to lock the connection blades in place, you have not properly latched the connection blades in place. Push on the back of the connector blade until it latches over the end of the spring. It may take a goodly amount of force.

Properly assembled APP connectors normally have sufficient pull-out resistance for all but the most unusual forces.

73,
Don W3FPR

On 2/17/2015 9:58 AM, Chris Hallinan wrote:
Hi list,

I've noticed that almost every time I move my K3, it powers down.  I
have little doubt it's the power pole connectors.  I soldered them,
and I'm pretty good with a soldering iron.  It seems to be plugged in
and fully seated.  But why is it so fragile?  I used the powerpole
connectors and contacts that came with my K3 kit.

Has anyone else notice this phenomenon?  Any advice?



______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to