Well, I made some measurements tonite. Using the k2 counter to track the BFO and an external counter to track the PLL, I measured from cold start to 45 minutes, with no transmitting. The results: PLL drifted 50hz UP, and the BFO drifted 60 hz DOWN. Perfect for the higher bands where they almost cancel, but not so for the lower bands where they add (do I have that right?). Does anyone have any info on frequency compensating the oscillators using negative coefficient caps?
----- Paul, N2PD -- View this message in context: http://elecraft.365791.n2.nabble.com/Using-X-lock-to-stabilize-PLL-osc-tp7610743p7610820.html Sent from the Elecraft mailing list archive at Nabble.com. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected]