John,

Try to run the TX Gain Calibration manually.  See the KX3 manual page 33.
That will tell you whether it fails on only some bands, but not others. The Utility program quits after the 1st error. If the manual calibration succeeds, then you might want to try the Utility process again, but it is not necessary.

73,
Don W3FPR

On 1/10/2016 11:08 AM, VE3NFK wrote:
Hello

Just finished updating firmware; using latest utility pgm; radio works fine
  - 'tune' into dummy load gives 1.1-1.

  Calibration from utility instantly fails at 1.900 99.9-1 SWR.

Can't think of anything to try - commercial dummy load directly connected.



______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to