Ed,
Remove all coax and other cables except power from the K3, then connect
a dummy load.
If the HI SIG message is still present, it is likely there is an
internal K3 problem.
If the message goes away, start connecting things one at a time to
determine which is causing the problem.
73,
Don W3FPR
On 3/5/2016 1:27 PM, KD7PY wrote:
Just tried to do the ( PARAMETER INITALIZATION ) per the manul...
when powering on a holding shift-lo knob in I get EE INT, norm, hi sig
one message, one after another..
still locked up. looks like I might have to send it to the boys at
Elecraft. hope I can do the repair myself
if not to involved.
Ed KD7PY
--
View this message in context:
http://elecraft.365791.n2.nabble.com/K3-HI-SIG-on-the-display-tp7614930p7614936.html
Sent from the Elecraft mailing list archive at Nabble.com.