Get some no. 10 stranded wire at Home Depot (etc.), double it over, put one end
in a vise and the other in the chuck of your electric drill and twist away. Not
shielded, but much better than parallel wires. I suppose you could strip some
RG-8 if you really wanted to shield it.
Vic 4X6GP
On 20 Jun 2016, at 22:54, DGB <[email protected]> wrote:
Jim ... where does one find #10 twisted pair? Is it shielded?
thanks 73 Dwight NS9I
On 6/20/2016 12:59 PM, Jim Brown wrote:
On Mon,6/20/2016 10:33 AM, James Walker wrote:
Is it normal to register voltage as low as I’m seeing on my K-3?
What you're seeing sounds like IR drop in the DC cable. How long is the DC
cable between the K3 and the power supply? What wire gauge? Is there any
equipment (like distribution panel) in between?
This is a great application for a short length of #10 twisted pair between the
PSU and rig.
73, Jim K9YC