On Wed,3/1/2017 5:25 AM, Charlie T, K3ICH wrote:
Is there any truth in the theory of making the vertical radiator out of
multiple wires such as ladder line and even adding a third wire woven through
the ladder sections and fed on one wire?
Nope. And that's not "theory," that's someone's dumb idea. :)
BUT -- using multiple spaced conductors in parallel and connecting them
at both ends makes the conductor "thicker," which both lengthens it 1-2
percent and broadens the SWR bandwidth. The same thing happens with a
tower as compared to a single wire. The vertical part of my 160M Tee
vertical is a pair of #12 spaced about 9 inches. When I added the second
wire, I observed that my SWR bandwidth approximately doubled.
73, Jim K9YC
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]