I bought a couple of these (TT3G50) from DX Engineering.  Unscrewed the gas discharge plug, took a look and some photos of the inside construction, and sent them back.  Simply awful, (Alpha-Delta, not DX Engineering)   BTW, the only "protection" is a 1000V breakdown gas discharge tube with questionable contact to the coax center conductor.

Wes  N7WS

On 1/21/2018 5:12 PM, Paul Christensen wrote:
[snip]
High power Alpha-Delta arc-plug devices are located at the master ground bus where all coaxial and control lines enter the station. Low power (200W) Alpha-Delta devices are installed between the K3 and amplifiers. The Alpha-Delta devices use field-replaceable arc-plugs. Like Polyphaser, these devices are intended to mitigate lightning-induced charge, not necessarily antenna static charge. Still, it's possible that one or more of the Alpha-Delta arc plugs has failed, leaving the K3 vulnerable to static damage.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]