Hello Don.  when I talked to the guy at elecraft, I am almost positive he said 
slow blow fuses.  In the manual' it says 3 AG fast blow.  Really confused here. 
 Looked at the power cord that Mike sent with the amp.  It's a 220 power cord.  
Ordered a heavy duty 15 amp power cord today.  I have a 10 amp but don't think 
it is heavy duty like the guy said to use. 


Does elecraft have a way of ordering replacement parts or a source where they 
get their parts.

KB4OIF

John


> On July 14, 2018 at 2:04 PM Don Wilhelm <[email protected]> wrote:
> 
> 
> John yes, 12 amp 240 volts will work fine.  The voltage rating for a 
> fuse is "any voltage up to the rated voltage".
> 
> The manual statement to use "12A fuses for 115V" does NOT mean that the 
> fuses must be rated for 115V.
> 
> 73,
> Don W3FPR
> 
> 
> On 7/14/2018 1:43 PM, John Clemmer wrote:
> > Hello.  new owner of a KPA 500 and KAT 500.  Previous owner is a good 
> > friend of mine.  He had 220 in his shack. He had 6 amp fuses in it.    I 
> > have 110 and am looking hard for fuses for the KPA 500.  Manual says two 12 
> > amp fuses for 115V.  tech said use slow blow ones.  Any suggestions.  Can't 
> > seem to find a forum for Elelecraft.  Will 12 amp 230 v work????

John
KB4OIF
Proud Vietnam Vet
Freedom is not free, someone paid!!!
There would be no freedom without the military........
In GOD, we trust.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to