YES! This is a chronic problem with Astron supplies -- I've never seen
one that didn't have this problem! I first discovered and documented
this issue almost 10 years ago. In one supply, the two clam-shell
sections of the chassis were also insulated from each other by paint!
This failure could easily cause instability!
http://k9yc.com/PowerSupplyBondingAndAudioDistortion.pdf
73, Jim K9YC
On 2/25/2019 6:24 PM, Bob McGraw K4TAX wrote:
I have personally found several instances in power supplies I either
own or have repaired where the green power wire lug is firmly attached
by the bolt and nut. It however was nicely insulated by the
paint!. Visual inspection is the best way to determine if an issue
exists. Do take time to remove the bolt and nut securing the wire lug
to the chassis. Clean the area to bright shining metal where the lug
would come in contact with the chassis. Then reattach the green wire
and lug with the original nut and bolt.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html