Russ,
Your statement of "no resistance" is misleading. Several hams use that
to indicate infinite resistance - because of the way their meter reads
(blank reading) where in other cases, hams use that phrase to indicate
zero ohms.
In the future, be clear and use a numerical value - infinity is a
numerical value.
The Collector to ground resistance will normally be in the vicinity of
1500 ohms and climb as the meter charges the electrolytic capacitors.
73,
Don W3FPR
On 6/24/2020 11:35 AM, Russ Edelen wrote:
Thanks Don. That confirms the notion I had about needing the
replacement kit.
Russ
KG7VQ
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]