Thanks, Don, I’ll check it out when I have a chance next week. I appreciate 
your suggestions. At the moment, the K60XV and the K2 are about 35 miles apart….

> On Nov 28, 2020, at 5:53 PM, Don Wilhelm <[email protected]> wrote:
> 
> Bill,
> 
> You might want to inspect the K60XV soldering carefully for bridges and 
> anything unsoldered.
> 
> When this fault condition occurs, what is the voltage on K60XV P1 pin 6.  If 
> VRFDET becomes active during receive, the K2 may behave as you describe 
> because the firmware 'thinks' the K2 is transmitting.  The fact that you do 
> not see it on the transverter bands further amplifies my thoughts on the 
> source of the problem being the VRFDET signal.
> 
> I cannot think of a component problem that would create your condition, so 
> that is why I asked you to review the soldering.  Look at the component 
> placement too - make sure all the components are in the right hole and not in 
> a nearby via hole.  Check D3 and D4 for proper orientation.
> 
> 73,
> Don W3FPR
> 
> On 11/28/2020 5:21 PM, Bill Coleman wrote:
>> A few weeks ago, I managed to cobble enough of the parts together to build a 
>> K60XV. It came together great, and works both on 60m as well as a base for a 
>> transverter.
>> I thought that would have been the happy end of the story, except I’ve had 
>> some odd trouble with it installed. I saw this briefly the day after the SS 
>> CW contest, and on the second day of the SS Phone contest. In each case, 
>> removing the K60XV solved the problem and it did not recur.
>> Here’s what I’ve observed. After leaving the K2/100 turned on for several 
>> hours, the rig is in receive mode, but the AGC is fully activated, with all 
>> ten bars showing on the S-meter. The receiver audio is entirely blanked.
>> This condition is intermittent and random. It tends to last for several 
>> seconds to many minutes. It happens on all bands at the same time EXCEPT it 
>> does NOT happen on any TRN band that is configured (I have one configured 
>> for 50 MHz/28 MHz). This lead me to believe the K60XV was involved. During 
>> the SS Phone, I removed the K60XV and replaced it with a Re-work eliminator 
>> and K2/100 and the rig worked just fine for the next 10 hours.
>> During the last three days, I opened the K2 up and laid the KPA100 on the 
>> workbench and left the K2 powered up with the K60XV installed. The problem 
>> manifested itself within hours. I was able to run a few diagnostics.
>> The AGC activation happens in all all AGC modes, SLO, FAST and OFF. I was 
>> able to get a scope probe on the emitter of Q12 on the Control board. When 
>> the blanking occurs, I see a train of pulses around 2 mS apart - around 500 
>> Hz.

Bill Coleman, AA4LR, PP-ASEL        Mail: [email protected]
Web: http://boringhamradiopart.blogspot.com
Quote: "Not within a thousand years will man ever fly!"
            -- Wilbur Wright, 1901

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected] 

Reply via email to