I am suffering from a similar problem in the midst of applying the various 
upgrades. My BFO test numbers are good,
4917.13 kHz
4912.16 kHz
4.97 kHz range

but when I try the VCO linearization process, I see 11090 flash and then get 
error 232. I have not checked the VFO against a reference frequency. I have 
tried two different crystals and several different L31 values.

My planned next step is to assemble the RF probe and see if I can figure out 
what is going on.

Doug, W0UHU.

> From: M Bak <[email protected] <mailto:[email protected]>>
> 
> Issue. Unable to undertake VCO alignment. 

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected] 

Reply via email to