Today when using my KPA500 I switched it into operate mode from standby and
received an error message of 270V ERR. This is the first time I have seen
this error. I partially disassembled the amplifier and measured the 270V
voltage and it is 70V, which is close to what the HV voltage measured on
the front panel says. After finding some old outdated schematics on the
internet it looks like there is a diode capacitor voltage
multiplier circuit that takes the HV voltage of approx 70V and brings it up
to 270V. I am assuming I have lost one of the diodes in the chain.
Unfortunately Elecraft has used tiny diode packs and even put 2 of the 3
packs between electrolytic capacitors on the board, which I will have to
remove. Has anyone else seen this problem with their KPA500? And how did
you go about fixing this?

Thanks,
Bruce, WB6IZG
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 

Reply via email to