On 3/2/2022 9:38 PM, Dr. William J. Schmidt wrote:
I have a KPA500 that faults on low (60 VDC) voltage.
Hi Bill,
It MIGHT be faulting because the HV is too low. It's an un-regulated
supply, so if line voltage is low, HV will be low. There's a jumper to
re-tap the power transformer, accessible with the top off, details in
the manual. We used to run into that when running two K3/KPA500 stations
on the same 2kVA Honda on county expeditions for 7QP and CQP.
73, Jim K9YC