If you check the schematics, the 270V is made/comes from the power supply...
BUT the 60V enable relay (feeds the voltage divider and read on the front
panel) is on the PA board... 

-----Original Message-----
From: [email protected] <[email protected]> On
Behalf Of Andy Durbin
Sent: Sunday, July 17, 2022 7:35 PM
To: [email protected]
Subject: [POSSIBLE SPAM] Re: [Elecraft] KPA500 / 270V ERR

"I think it may actually be the other way around... The 60V relay does not
close if 270V is missing?"

Assume 60 V Enable relay K1 is not closed.  How would 270 V be produced?
The secondary winding of T1 is open circuit.