"If you check the schematics, the 270V is made/comes from the power 
supply...BUT the 60V enable relay (feeds the voltage divider and read on the 
front panel) is on the PA board... "

May I suggest that you look at KPA Power Supply Schematic sheet 1 of 2 and 
locate relay K1 (60 V Enable) which is controlled by the interlock switch and 
signal 60 V ENBL.

How is 270 V produced if this relay is open?

How is 270 v produced if 60 V is not present?

I do not think it a coincidence that the OP has lost 270 V and 60 V.  I suspect 
a common cause.

Andy, k3wyc