Hi folks
Just building my K2. Got as far as the first resistance checks on the RF
board (page 38)
All values test correct but one.
The right end of R115 is meant to be >500 ohms to earth.
With an analogue meter it gives 2 ohms.
With a DMM on auto range it flashes between ranges wildly. But on manual
range it gives 10.2 Kohms.
Anyone shed any light on this?
Thanks
Jack