Running 100W output on 20m, using the in-built two tone test oscillator, I measure the third order products at -30 dB relative to peak (ARRL method of measurement) and 5th order at -40 dB.

There was a suggestion the internal two tone test oscillator gives better results by some 3dB than can be obtained by feeding an external two tone into the K3... That would put the above figures at about the same as the ARRL measurements.

73 Dave, G4AON