Bear with me, this is strange....  K2 / 06254  built last Fall

A few days ago I fixed a problem on my K2 (low output on 15/12/10). Yesterday I finished a complete alignment and today reinstalled the KPA100.

So... its lashed to a dummy load and I'm stepping through the bands to make sure the KPA100 is happy. I get to 12M and the VFO happens to be set to 25000.00, I tap the key. No output and I get an "END" message on the display.

Move the VFO to inside the band, no more "END" message but still no output. Change the power level - now there is normal output!

In fact, if I recreate the setup (freq to 25000.00 or higher, tap the key, get "END"), then change to any other band - there is no output until I change the power setting.

I couldn't find this mentioned in any of the archives. Is the firmware getting confused or do I have a unique gremlin? The only reference to the "END" msg I can find in the book is CAL PLL.

It's working 100% otherwise. Would appreciate it if somebody else would give this a try!

THX & 73,  Bill  N2BC