Jerry Flanders wrote:
Most amps in common use provide a negative-going ALC voltage. And most
rigs in common use are compatible with this. The K3, however, requires
a positive-going voltage.
According to the K3 FAQ at
http://www.elecraft.com/K3/K3FAQ.htm#SignalArchitecture , " Once ALC
is working to our satisfaction, we'll provide simple interfacing
information that will allow the use of negative control voltages
(probably a resistive divider pulled up to a positive supply, or at
most an op-amp circuit)."
Jerry,
The ALC function is still disabled, but I plan to turn it on and
provide the interface details by the end of this week. Would you like
to test the implementation prior to general release?
73,
Wayne
N6KR
---