Mike Short wrote:
Will RG-174 handle 100W at HF/6M?

For the reasons  given in other posts, I wouldn't trust it.

One thing I've seen with RG174 is migration of the center conductor caused by I^2R heating where the cable is bent into a small radius. It does not take much shift to cause a center conductor-to-braid short.

If you have to use a small diameter cable because of physical limitations, I would go with a Teflon equivalent, such as RG-188.

Jack K8ZOA
www.cliftonlaboratories.com
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply via email to