djmd wrote: > > Well, now I'm even more confused. I installed those toroids. I checked the > pads for connectivity, and they are ok. The signal seems to be present on
Both ends of the filter are grounded when the filter is not selected, and the power off relay positions are not defined (probably last setting). That could give a false indication of continuity. > the "top" pad of L25 and L26, but still nothing on C226 or C227. I guess I > should remove them, re-wind them and re-strip/tin? Like I said, I checked > them on the DMM but I guess I'm not 100% sure. I'm having way more trouble > stripping the enamel off these than I did with the KX1 for some reason. > -- David Woolley "The Elecraft list is a forum for the discussion of topics related to Elecraft products and more general topics related ham radio" List Guidelines <http://www.elecraft.com/elecraft_list_guidelines.htm> _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com