Ed,

The crystal grounding on X2 thru X5 is designed to allow space for the 
batteries.  So that is not the source of your prroblem.

73,
Don W3FPR

EMD wrote:
> Hi Don,
>
> I think I may have found the problem.  When I installed X1 I attached  
> a ground to the top of the crystal.  I used the same technique when I  
> installed X2 through 5.  After rereading the installation portion of  
> the manual I read that the ground should be attached no more than  
> 3/16" from the bottom of the crystal.  Do you think this is the problem?
>
> Thanks
>
> Ed
>   
>