Hi folks! Thank you for suggestions. In my previous post, I forgot to say that my K3 works without hi-temp alarm after warming up (about 30min or so without transmit just receiving status).
So, it's just the same with Jaako's case. My shack temp was around 15C these days. hmmm... Atsu, JE1TRV > Hi > > I have same problem, when shack temperature is below 17 degrees Celcius > > When PA Temp is higher than 25 degrees C then power is OK. > > Jaakko OH1MA / K3 ser. 2952 > > > Hi Elecrafters! > > I have problem on my K3/100 (S/N3050, factory assembled). > When I transmit more than 12W(means hi power amp on) > within about 30min after mains power on, HI-TEMP alarm > occur and equipment is forced to set 5W. > > No problem at all when hi-power amp is through ( Po<12W ). > > Any idea? > Thanks in advance > 73, Atsu JE1TRV > > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html