I have a low resistance on the power poles for my first resistance check and R36, but U12 and U13 are OK. I disassembled the sides and front panel, checked for missed masking tape or other issues,reassembled everything, and have repeatable low results. I verified resistance measurements by checking known resisters.
Low 12VDC PP connectors. Required: >3K ohms Measured: 1.85K ohms Low R36 and ground. Required: >150 ohms, measured: 100 ohms OK U12 and ground. Required: >500 ohms, measured: 1.85K ohms OK U13 and ground. Required: >150 ohms, measured: 2.50K ohms I think this is telling me I have I started with a multi-range DMM, but discovered an intermittent probe and had to use a single range (x1K ohm scale) analog meter. Will try to get a replacement tomorrow. Any suggestions for possible causes will be appreciated. This is my third kit (Rock-Mite, K1 and now a K3). Thanks NU6T Rich ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html