Glenn, This happened to me recently, and in my case it was a TMP cable between the KREF3 board and the RF board that had become dislodged. No doubt there are other possible causes, but that's a relatively easy one to check.
73, Rich VE3KI K5ZE wrote: > I have K3 serial number 2802 with the 100 watt option. All was well until > today. > Currently there is zero to minimal output. > Rotating the power knob to 12 watts you hear the relay. Regardless of power > setting > only 1 bar on the RF is lit.The fans are workings. > Rechecking the TX calibration it failed at 5 watts with the ERR TXG message > on the display. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html