Don, some other considerations:

1). What about the other components inside the XV?  If the power module is 
happy running at 100C what does that do for everything else in the XV running 
at 60-70C with no airflow?

2). My ambient temp in the shack during EME is 80F even with the house A/C 
running due to the tube PA.

3). Does the XV144 run at the same efficiency (waste heat output) as the XV50?

Thanks for your assistance. I look forward to your measurements. 

73

Eric WD6DBM 

Sent from my iPhone

On Jun 3, 2010, at 9:02 PM, Don Wilhelm <[email protected]> wrote:

Johnny,

Prior to testing, I have reviewed the datasheet for the RA30H0608M module that 
is used in the XV50.  The power module is specified to operate within spec at 
110 degrees C ( 230 deg F).  While that is too hot to touch (in excess of 
boiling water temperatures), it is well within the device specifications.  SNIP




















______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to