Sebastian, The extraneous spaces were only in the email, I have to retype it since the computer I am emailing from is separate from the development computer. I tried all sorts of combinations of referencing the BIT file. Among them was to copy SVST8_4.BIT into the "bin" folder and then reference it as firmware=bin/SVST8_4.BIT. Every way I do it I get the exact same error:
hm2_5i20: Unknown parameter "num_stepgens" Regards, Eric There are extraneous spaces there, and unless you specifically added the symlink it probably doesnt know what to do with "firmware=bin/...". It should be something like this: loadrt hm2_5i20 config="firmware=SVST8_4.BIT num_stepgens=2" ------------------------------------------------------------------------- This SF.Net email is sponsored by the Moblin Your Move Developer's challenge Build the coolest Linux based applications with Moblin SDK & win great prizes Grand prize is a trip for two to an Open Source event anywhere in the world http://moblin-contest.org/redirect.php?banner_id=100&url=/ _______________________________________________ Emc-developers mailing list Emc-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-developers