Hi Guys
Looking for opinions on Classicladder ver 7.124 in TRUNK:
Keeping in mind EMC 2.3 it's acceptable to break configs:
CL V7.124 has slightly different timers that require a small
change in the ladder program to work the same (you must
connect two ladder pins together). This allows added features
to the timer. Right now I force the added pin to act connected
But would prefer not to do that-one less thing to change
from main stream CL and you lose the added features.
CL V7.124 defaults to 15 each of hal in/out pins while
CL V7.100 had 50 each. To me 100 pins adds a lot of
clutter but any existing config that uses more then 15
pins needs a change.
There are lots of changes from V7.100, and lots of work
on the serial MODBUS routines.
any comments would be appreciated.
Thanks
Chris Morley