2014-10-03 0:29 GMT+03:00 Dave Cole <[email protected]>:
> I'm using M64 P0 to turn on the waterjet and M65 P0 to turn it off.

Any particular reason not to use M3/M5 commands? At least I did that
on my waterjet, customer never commented about that. It just seems
like common sense - tool on and tool off, whatever is the tool -
spindle, jet of water, electric arc in plasma.
Anyway, inserting those G41.1/G42.1, when jet-on and G40 on jet-off
moments seems like the easiest way.