On Friday 15 July 2016 09:17:20 Daniel Rogge wrote:

> Kirk Wallace modified G76 for us to accept a taper value.  The
> modified version takes a D parameter for taper, but the lead in/out
> tapers had to be removed from the cycle for a compatibility reason
> that I've forgotten.  Kirk may have more information.  If you are
> interested I'll send a patch.
>
> Rogge
>
That is another concern that I am coding into this. Losing the  
leadin-leadout is a fatal flaw for this.  The tool must be retracted 
enough to clear the thread peaks during the retrace.  For boring or 
turning, one can retrace with the tool in contact, but not for 
threading. So I don't think the patch would do me any good.

Thanks for the offer though, Rogge.

Cheers, Gene Heskett
-- 
"There are four boxes to be used in defense of liberty:
 soap, ballot, jury, and ammo. Please use in that order."
-Ed Howdershelt (Author)