> It is read every time motion runs - the intention is that it
> is a fast-acting way to modulate the federate.  Possible
> values are 0.0 (feed hole) to 1.0 (feed at normal rate).
> 
> The original target was EDM - adaptive feed would be
> connected to something that measures spark rate and/or
> voltage and modulates the feed to maintain the proper gap.

I tried for EDM but with a branch which also could handle backward motion.

------------------------------------------------------------------------------
_______________________________________________
Emc-developers mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-developers

Reply via email to