On 03/31/2017 12:48 PM, Stuart Stevenson wrote: > results as follows > > start machine > encoder count = 0 > ilowpass in = 0 > ilowpass out = 0 > > move positive one click > encoder count = 4 > ilowpass in = 4 > ilowpass out = 3
Is your ilowpass.scale = 1? That's surprising to me. On my machine (which cradek configured) the scale is 250. I have 4 encoder edges per MPG detent, so i get 1,000 counts out of ilowpass per detent. Maybe I have the same off-by-one problem on the output that you describe, but it's only got a 1/250 part of the effect. I've never noticed a problem like this, but i've never payed close attention to the numbers. I'll try to remember to look at it the next time I power my mill up. -- Sebastian Kuzminsky ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ Emc-developers mailing list Emc-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-developers