On 03/31/2017 12:48 PM, Stuart Stevenson wrote:
> results as follows
>
> start machine
>       encoder count = 0
>       ilowpass in = 0
>       ilowpass out = 0
>
> move positive one click
>       encoder count = 4
>       ilowpass in = 4
>       ilowpass out = 3

Is your ilowpass.scale = 1?  That's surprising to me.  On my machine 
(which cradek configured) the scale is 250.

I have 4 encoder edges per MPG detent, so i get 1,000 counts out of 
ilowpass per detent.  Maybe I have the same off-by-one problem on the 
output that you describe, but it's only got a 1/250 part of the effect. 
I've never noticed a problem like this, but i've never payed close 
attention to the numbers.

I'll try to remember to look at it the next time I power my mill up.


-- 
Sebastian Kuzminsky

------------------------------------------------------------------------------