TJ>We have a product coming up in which it has been
TJ>proposed the PE Ground be terminated through an
TJ>anodized coating by a bolt, `star washer' and nut
TJ>clamping onto a channel.
TJ>I disagreed. I feel for PE to be `reliably connected' (
TJ>UL1950 Sec. 2.5) would require a stud or a threaded
TJ>hole cut after the anodizing into which a screw
TJ>terminating the PE ground lug would be installed.
TJ>What is the considered opinion of the group of
TJ>termingating PE to an anodized (nonconductive) metal
TJ>with a `star washer'?
Some anodizing is so tough I doubt if a star washer could cut through it
(got a box like that once from Philips Electronics, NL) therefore I
would not count on it being a reliable connection even if it showed
continuity.
If they have their hearts set on a bolt with nuts, simply mask off a
ring around the mounting hole, the star washer will always cut through
that thin layer of oxide.
- Robert -
[email protected]
---