Wouldn't be OK to rely upon the star washer if production had 100% ground continuity testing at the same time that hipot is performed?
Regards, [email protected] ---------- From: tjmeck To: emc-pstc Subject: PE Grounding UL 1950 ITE List-Post: [email protected] Date: Monday, September 23, 1996 3:53PM Hello again. We have a product coming up in which it has been proposed the PE Ground be terminated through an anodized coating by a bolt, `star washer' and nut clamping onto a channel. I disagreed. I feel for PE to be `reliably connected' ( UL1950 Sec. 2.5) would require a stud or a threaded hole cut after the anodizing into which a screw terminating the PE ground lug would be installed. What is the considered opinion of the group of termingating PE to an anodized (nonconductive) metal with a `star washer'? Best regards, Terry J. Meck Senior QA/Test Engineer 215-721-5280 [email protected] Accu-Sort Systems Inc. Telford, Pa USA