Hi group,

There is a paragraph of "6              Performance criteria" on Page 5 of EN 
50082. It describes Performance criterion A, B and C.

On the other hand, there is a  paragraph of "9  Test results and test 
report" in 1000-4-2, 1000-4-3, 1000-4-4, 1000-4-5, 1000-4-6 and so on. It 
asks us to classify the test results in four classes: a), b), c) and d). 

The above A, B and C overlap what a), b), c) and d) are covering. 
Unfortunately, they are not totally consistent. You can find a part of b): 
"temporary ... loss of function ... self-recoverable" in 1000-4 series is 
the same as a part of Performance criterion C: "Temporary loss of function 
... self-recoverable" in EN 50082-1. As you all know, EN 50082-1 calls for 
1000-4 series as basic standards.

What do think of the inconsistency?

Thank you.
Best Regards,
Barry Ma
 



---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to majord...@ieee.com
with the single line: "unsubscribe emc-pstc" (without the
quotes).  For help, send mail to ed.pr...@cubic.com,
ri...@sdd.hp.com, or roger.volgst...@compaq.co (the list
administrators).