Hello Muriel, I believe "CISPR 15:1996 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment" would be the right choice. Part 5.4.3 Independent transformers and converters for incandescent lamps. Or Part 5.4.4 Independent ballasts for fluorescent and other discharge lamps. Use Table 2a (mains connection) and 2b (secondary connection(s)). Best regards Helge Knudsen [email protected]
---------- From: Muriel Bittencourt de Liz[SMTP:[email protected]] Reply To: Muriel Bittencourt de Liz Sent: 29. september 1998 23:52 To: Lista de EMC da IEEE Subject: Information on lighting electronic transformer Hello Group, I'm doing some tests of conducted emissions on lighting electronic transformers ( 120VAC / 12V ) and i have a doubt: which standard applies to this kind of product? i think there are two possibilities: - household appliances standard - lighting equipment Could anyone help me with this? Best Regards Muriel -- ================================================== Muriel Bittencourt de Liz INEP - Instituto de Eletronica de Potencia Universidade Federal de Santa Catarina Caixa Postal - 5119 88.040-970 - Florianopolis - SC - BRASIL Phone: +55.48.331.9204 - Fax: +55.48.234.5422 e-mail: [email protected] Homepage: http://www.inep.ufsc.br ================================================== --------- This message is coming from the emc-pstc discussion list. To cancel your subscription, send mail to [email protected] with the single line: "unsubscribe emc-pstc" (without the quotes). For help, send mail to [email protected], [email protected], [email protected], or [email protected] (the list administrators). --------- This message is coming from the emc-pstc discussion list. To cancel your subscription, send mail to [email protected] with the single line: "unsubscribe emc-pstc" (without the quotes). For help, send mail to [email protected], [email protected], [email protected], or [email protected] (the list administrators).