Several years ago my company exercised this exemption because our equipment
at that time was extremely large and somewhat difficult to stage. More
recently, we have elected to test and verify to FCC or CISPR regulations. 

One word of caution. The exemption by the FCC may still be valid, but as I
understand it, this merely eliminates the need for testing. It does not
eliminate the responsibly to correct subsequent EMI problems.

Rick Busche
Evans & Sutherland
[email protected]

                -----Original Message-----
                From:   [email protected]
[mailto:[email protected]]
                Sent:   Wednesday, January 13, 1999 11:41 PM
                To:     '[email protected]'; [email protected];
Luttrell, Lyle
                Subject:        RE: FCC exemptions 

                Thanks Lyle and everyone,

                The answer seems to be not in part 18 but in the detail of
the OET document.

                It seems the intention was to exempt "maintenance, research,
evaluation, simulation, and other 
                analytical or scientific applications". Whatever that might
mean. In some cases the same device 
                (e.g. a scanner) could be for testing something or producing
something.

                It is still something which may be open to argument, and
since FCC is a federal regulation, the 
                argument could start when the device is introduced into the
US (customs?)

                Did anyone experience such an argument versus FCC?

                thanks again,
                Moshe
                --------------------------------------------
                Name: moshe valdman
                E-mail: [email protected]
                Phone: 972-52-941200
                Telefax: 972-3-5496369
                Date: 13/1/99
                Time: 22:40:49
                You are most welcome to visit my homepage at:

                http://www.geocities.com/CapeCanaveral/5233/
                --------------------------------------------


                ---------
                This message is coming from the emc-pstc discussion list.
                To cancel your subscription, send mail to [email protected]
                with the single line: "unsubscribe emc-pstc" (without the
                quotes).  For help, send mail to [email protected],
                [email protected], [email protected], or
                [email protected] (the list administrators).

---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes).  For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).

Reply via email to