UL 1950 3rd edition clause 5.4.9 - The test is made as specified in 5.3.2
after the insulation has cooled to room temperature

-----Original Message-----
From: [email protected] [mailto:[email protected]]
Sent: Thursday, December 16, 1999 2:38 PM
To: [email protected]; [email protected]
Subject: RE: Electric Strength After Abnormals


Peter,

I don't know where it's actually spelled out but, I've always checked
electric strength immediately following abnormals (blocked vent / rotor).
This is when insulation is most likely to degrade or fail.

George

> -----Original Message-----
> From: [email protected] [SMTP:[email protected]]
> Sent: Thursday, December 16, 1999 10:45 AM
> To:   [email protected]
> Subject:      Electric Strength After Abnormals
>
>
> Dear All,
>
> After an Abnormal Test for UL1950/EN60950, should the Electric Strength be
> done a) immediately after the Abnormal Test or b) after Abnormal Tesrt
when
> unit has cooled down to room temperature c) after Abnormal Test when unit
> has cooled down to Normal Heating Temperature Levels.
>
> The standards are not clear!
>
>
> +++++++++++++++++++++++++++++++++++
> RTTE Directive Seminar
> Renaissance Hotel, Tel-Aviv
> 12th January 2000. For details:
> http://www.itl.co.il/RTTE.htm
> +++++++++++++++++++++++++++++++++++
>
>
> Peter Merguerian
> Managing Director
> Product Testing Division
> I.T.L. (Product Testing) Ltd.
> Hacharoshet 26, POB 211
> Or Yehuda 60251, Israel
>
> Tel: 972-3-5339022 Fax: 972-3-5339019
> e-mail: [email protected]
> website: http://www.itl.co.il
>
>
>
>
>
>
> ---------
> This message is coming from the emc-pstc discussion list.
> To cancel your subscription, send mail to [email protected]
> with the single line: "unsubscribe emc-pstc" (without the
> quotes).  For help, send mail to [email protected],
> [email protected], [email protected], or
> [email protected] (the list administrators).
>

---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes).  For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).


---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes).  For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).

Reply via email to