Hi Ed

At a power frequency field of 1 A/m you start to recognize a
disturbance. At 3 A/m most people get annoyed. These figures may
vary +/- 6 dB depending of the monitor type.

Best regards
Viggo Broendegaard
[email protected]
DELTA Electronics Testing



>>> <[email protected]> 13-07-99 03.03 >>>

Hi Listmembers!

Does anyone have an estimate of the magnetic field immunity levels of
recent production computer monitors? What levels, in Gauss or Tesla,
do monitors actually start to show disturbance? And at what levels
could you expect a typical monitor to be not just annoying, but virtually
useless?

Thanks,

Ed

--------------------------
Ed Price
[email protected]
Electromagnetic Compatibility Lab
Cubic Defense Systems
San Diego, CA.  USA
619-505-2780