Hi Listmembers!

Does anyone have an estimate of the magnetic field immunity levels of recent 
production computer monitors? What levels, in Gauss or Tesla, do monitors 
actually start to show disturbance? And at what levels could you expect a 
typical monitor to be not just annoying, but virtually useless?

Thanks,

Ed

--------------------------
Ed Price
[email protected]
Electromagnetic Compatibility Lab
Cubic Defense Systems
San Diego, CA.  USA
619-505-2780
List-Post: [email protected]
Date: 07/12/1999
Time: 17:03:14
Military & Avionics EMC Services Our Specialty
Also Environmental / Metrology / Reliability
--------------------------



---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes).  For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).

Reply via email to