Hello Group,
 
 
        Table 1 of EN55024 calls for a test specification of 3 V/m
(umodulated, r.m.s) radio-frequecny EM field for Immunity at the enclosure
port. 
 
        Does anyone know off-hand the value when the signal is 80% modulated
with an AM signal of 1kHz as called for in the same table?
 

Antonio Cinquino 
CAE Electronics Ltd. 
Electrical System Designer 

Phone : (514) 341-2000 (ext. 4303) 
Fax      : (514) 340-5552 
Email  : [email protected] <mailto:[email protected]>  

 

-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Jim Bacher:              [email protected]
     Michael Garretson:        [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]

Reply via email to