KTL Ottawa is the only I know of which Korea will accept EMC/EMI results from.
Jim Bacher wrote: > Forwarding for George > > ____________________Reply Separator____________________ > Subject: RE: Korean Requirements > Author: "Seminsky; George" <[email protected]> > Date: 7/20/00 7:28 AM > > The last time I checked, South Korean safety is IEC950 based, analog > telephony is FCC part 68 based, and that EMC is CISPR22 based. However, the > Korean authorities will not accept test reports, certifications for other > countries. And a product must be tested, certified in either an in-country > lab or in a certified lab in a country that has an MRA with South Korea. > Check with KTL Ottawa for the latest information. > > George Seminsky > Compliance Engineering > Nuera Communications. Inc. > 10445 Pacific Center Court > San Diego, CA 92121 > Ph 858 625 9220 X1248 > Fx 858 625 2422 > www.nuera.com > > -----Original Message----- > From: Cameron O'phee [mailto:O'[email protected]] > Sent: Wednesday, July 19, 2000 4:54 PM > To: 'EMC - PSTC Forum' > Subject: Korean Requirements > > Hello All, > > I would like to get some advice on what is required to have products > approved for sale in South Korea. Our equipment has been tested for Safety > and EMC to Australian and European requirements. The Australian test house > that performs the safety testing can generate CB reports for safety. > Contrary to the advice of the CB website, our agent in Korea has been > informed that we would have to completely re-test our equipment for both EMC > and safety. Is this correct? > > The standards that we are currently certified to are as follows, > > Australia > Safety - AS/NZS 3260 > EMC - AS/NZS 3548 > > Europe > Safety - EN60950 > EMC - EN55022 and EN50082-1 > > This is my first e-mail to the group and I have to say that this forum has > been most educational. > > Regards, > > Cameron O'Phee. > Technical Officer. > EMC & Safety Precompliance. > Aristocrat Technologies Australia. > > Telephone : +61 2 9697 4420 > Facsimile : +61 2 9663 1412 > Mobile : 0418 464 016 > > ------------------------------------------- > This message is from the IEEE EMC Society Product Safety > > ------------------------------------------- > This message is from the IEEE EMC Society Product Safety > Technical Committee emc-pstc discussion list. > > To cancel your subscription, send mail to: > [email protected] > with the single line: > unsubscribe emc-pstc > > For help, send mail to the list administrators: > Jim Bacher: [email protected] > Michael Garretson: [email protected] > > For policy questions, send mail to: > Richard Nute: [email protected] ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: [email protected] Michael Garretson: [email protected] For policy questions, send mail to: Richard Nute: [email protected]