I'm back on RCIC.. Thanks for all your help. George -----Original Message----- From: [email protected] [mailto:[email protected]] Sent: Tuesday, September 26, 2000 6:23 PM To: George Sparacino Cc: EMC Newsgroup Subject: Thanks - RE: NEBS web site
George et al, Type the address in but also include at the end the standard default name for the html index document, as follows: http://www.rcic.com/index.htm What the guy did was redirect the default document. The default is typically index.htm or index.html I just tried it again to be sure it worked. Regards, Eric Lifsey Compliance Manager Naitonal Instruments Please respond to George Sparacino <[email protected]> To: "'David Spencer'" <[email protected]>, "'Guy Story'" <[email protected]>, EMC Newsgroup <[email protected]> cc: (bcc: Eric Lifsey/AUS/NIC) Subject: RE: NEBS web site Hello Group, BTW.. Access to RCIC is still trashed by the irrate Napster proponant ( [email protected] ).. has anyone found a work-around ? George -----Original Message----- From: David Spencer [mailto:[email protected]] Sent: Monday, September 25, 2000 8:35 PM To: 'Guy Story'; EMC Newsgroup Subject: RE: NEBS web site Guy, You can get NEBS information from the NEBS list server by signing up on the RCIC website http:\\www.rcic.com in the virtual conference hall under NEBS. While most of the members of the EMC group are also on the NEBS group, it is good to send requests to the right list. To start, you will want to get a hold of the following 3 documents: SR 3580 Defines the test levels GR 1089 CORE Electrical Criteria GR 63 CORE Environmental Criteria If you will be doing much in the way of network equipment, you will need others. I would suggest getting FR-2063-CD instead, as a minimum. Check out the family lists and see what fits your application. FR-2063 has the three documents mentioned above and GR 78 CORE. All Telcordia/Bellcore documents are available from the Telcordia store at http://telecom-info.telcordia.com/site-cgi/ido/index.html Try not to get sticker shock! You will find that Level 3 is everything in GR-63-Core and GR-1089-Core that applies to your equipment, i.e. if you have analog lines or connect to outside plan wiring, you will need to do everything. Best Regards, Dave Spencer Compliance Engineer Oresis Communications, Inc. 14670 NW Greenbrier Parkway, Beaverton, OR 97006 (503)533-0717 Dir: (503)466-6289 Fax: (503)533-8233 http://www.oresis.com [email protected] -----Original Message----- From: Guy Story [mailto:[email protected]] Sent: Monday, September 25, 2000 1:57 PM To: EMC Newsgroup Subject: NEBS web site Does anyone have a url for a web site that lists the NEBS Standards, specifically level 3? Thank you in advance. Guy Story, KC5GOI Compliance Technician Interphase Corporation Dallas Texas phone: 214.654.5161 fax: 214.654.5406 ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: [email protected] Michael Garretson: [email protected] For policy questions, send mail to: Richard Nute: [email protected] ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: [email protected] Michael Garretson: [email protected] For policy questions, send mail to: Richard Nute: [email protected]