I believe the surge test is applicable.  The zener avalanche diode barriers
provide protection to sensitive circuit components, but are the zeners
robust enough to withstand the surge?

If the signal line in question is one which, according to the standard, is
to be surge tested, the presence or absence of circuit protective elements
is immaterial. 
John P. Wagner
Lucent Technologies, Bell Labs
11900 N. Pecos St, Room 2F58
Denver CO  80234
email:  [email protected]
phone:  303 538-4241
fax:  303 538-5211

> ----------
> From:         Westin, Amund[SMTP:[email protected]]
> Reply To:     Westin, Amund
> Sent:         Thursday, May 11, 2000 1:15 AM
> To:   'emc-pstc'
> Subject:      EMC vs. Exi equipment
> 
> 
> Hello members,
> 
> One question, what's common practise regarding surge test (EN61000-4-5
> on signal lines) on lines which contains zener barriers ? Have a feeling
> that the surge test is not applicable.....
> 
> Comments ?
> 
> Best regards
> Amund Westin
> Det Norske Veritas
> * [email protected]
> 
> 
> 
> 
> **********************************************************************
> Neither the confidentiality nor the integrity of this message 
> can be guaranteed following transmission on the Internet. 
> This message has been swept by MAILsweeper at DNV for 
> the presence of computer viruses.
> **********************************************************************
> 
> -------------------------------------------
> This message is from the IEEE EMC Society Product Safety
> Technical Committee emc-pstc discussion list.
> 
> To cancel your subscription, send mail to:
>      [email protected]
> with the single line:
>      unsubscribe emc-pstc
> 
> For help, send mail to the list administrators:
>      Jim Bacher:              [email protected]
>      Michael Garretson:        [email protected]
> 
> For policy questions, send mail to:
>      Richard Nute:           [email protected]
> 
> 

-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Jim Bacher:              [email protected]
     Michael Garretson:        [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]

Reply via email to