EIRP=D^^2*E^^2/30
ERP=EIRP/1.64

The maximum effective radiated power of the TUTT integrating CMM 8600 modem
module is calculated using the following equations

where E is measured maximum electric field strength, 
D is the distance of 3 meters between the EUT and measurement antenna.

At 3/21/00, 03:49 PM -0800, [email protected] wrote:
>
> Hi all,
>I am looking for an ERP/EIRP calculator program. I get the raw data in
>dBuV/m from an OATS.
>Thx, Ron Chernus, Denso
>
>
>
>-------------------------------------------
>This message is from the IEEE EMC Society Product Safety
>Technical Committee emc-pstc discussion list.
>
>To cancel your subscription, send mail to:
>     [email protected]
>with the single line:
>     unsubscribe emc-pstc
>
>For help, send mail to the list administrators:
>     Jim Bacher:              [email protected]
>     Michael Garretson:        [email protected]
>
>For policy questions, send mail to:
>     Richard Nute:           [email protected]
>
>

Reply via email to