EMC Group, I am testing some ISM equipment to EN 50082-2 Heavy Industrial Immunity standards. For conducted RF immunity, it cites ENV 50141. My understanding is that an ENV a prestandard meaning the final standard has not yet been approved. We have EN 61000-4-6, which an approved conducted immunity standard. Is there any differences between ENV 50141 and EN 61000-4-6 and why isn't EN 61000-4-6 cited instead of ENV 50141. Sincerely, Daniel C. Kinney Lead Qualification Engineer
Horner APG, LLC Advanced Products Group 640 N. Sherman Drive Indianapolis, IN 46201 Phone: (317) 916-4274 ext. 462 FAX: (317) 916-4287 Email: [email protected] Website: http://www.heapg.com ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: [email protected] Michael Garretson: [email protected] For policy questions, send mail to: Richard Nute: [email protected]