I have encountered ITE with UL, CSA and TUV certification that uses wood as
the interior frame and enclosure. One must demonstrate that it is impossible
for a fire to start and to invoke clause 1.4.1 of IEC 950.
Richard Woods
----------
From: John Juhasz [SMTP:[email protected]]
Sent: Wednesday, January 26, 2000 1:05 PM
To: '[email protected]'; [email protected]
Cc: [email protected]
Subject: RE: Wood used inside ITE Equipment
Never saw wood in ITE equipment . . . other than in the 'Pirates of
Silicon Valley' movie. The
first Apple was built out of wood. I don't suppose we'd find too
much of that these days.
Seems to me that there should also be a spec for 'long term'
enclosure stability
based on 'termite resistance'!
Sorry . . . couldn't resist.
John Juhasz
Fiber Options
-----Original Message-----
From: [email protected] [ mailto:[email protected]
<mailto:[email protected]> ]
Sent: Wednesday, January 26, 2000 9:31 AM
To: [email protected]
Cc: [email protected]
Subject: Wood used inside ITE Equipment
Dear All,
There is a UL 1950 "PAG" stating that hardwood or presswood of
"substantial" construction is accepted without flammability tests
per Annex
A for products covered under UL1950.
The questions are:
1. What thickness is considered "substatntial"?
2. What other types of wood are considered acceptable without
flammability
tests?
3. What do European Test Houses require from the flammability
standpoint of
wooden enclosures or internal wooden materials?
Thanks
Peter Merguerian
Managing Director
Product Testing Division
I.T.L. (Product Testing) Ltd.
Hacharoshet 26, POB 211
Or Yehuda 60251, Israel
Tel: 972-3-5339022 Fax: 972-3-5339019
e-mail: [email protected]
website: http://www.itl.co.il <http://www.itl.co.il>
---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes). For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).
---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes). For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).