Hello PSTC members! I'm working on a product that is telecom network powered (-190 Vdc) and will most likely require a production line hipot test. Being network powered, it is exposed to outside plant surges and has transient protection designed in (fuse and sidactor).
UL's Follow-up Services gray pages states that "Transient voltage suppresion devices other than capacitors connected from primary wiring to dead metal may also be disconnected during the test." Will a production line hipot test be required? Has anyone had experience with this and how do you go about removing soldered sidactors to do the hipot test? It seems like this would be an extra step in the manufacturing process. All comments/opinions are welcome. Thank you, Jerry -- _______________________________________________ Get your free email from http://mymail.juno.com ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Michael Garretson: [email protected] Dave Heald [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: No longer online until our new server is brought online and the old messages are imported into the new server.