Jason,

You are correct.  All products placed on the market in the EU must be tested
to the latest standard once the magic date (DOW)  for the new standard is
reached.  Also, keep in mind that if a product specific standard is
published it takes precedence over the generic standard and the generic
standard no longer applies to the product family.  For example, EN
55024:1998 is the product specific immunity standard for ITE, so EN
50082-1:1997 is not used for these products.

This is one more example of why I refer to the EMC Directive as The EMC
Professionals Employment Act of 1989.

Ghery Pettit, NCE
Intel Corporation


-----Original Message-----
From: [email protected] [mailto:[email protected]]
Sent: Tuesday, November 27, 2001 1:10 PM
To: [email protected]
Subject: Revised EMC standards and CE Declarations. 



Hi all.

EN 50082-1:1992 was replaced by EN 50082-1:1997. According to the
newapproach.org website, from 1/7/2001 the old version no longer allows one
to presume conformity to the EMC Directive. 

Does this mean I need to retest all equipment to the new standard before I
can declare conformance?

My guess is YES. 

Thanks in advance for any confirmation or correction.

-Jason 
Product Safety Consultant




-- 




__________________________________________________________________
Your favorite stores, helpful shopping tools and great gift ideas.
Experience the convenience of buying online with Shop@Netscape!
http://shopnow.netscape.com/

Get your own FREE, personal Netscape Mail account today at
http://webmail.netscape.com/


-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Michael Garretson:        [email protected]
     Dave Heald                [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:
    No longer online until our new server is brought online and the old
messages are imported into the new server.

-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Michael Garretson:        [email protected]
     Dave Heald                [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:
    No longer online until our new server is brought online and the old 
messages are imported into the new server.

Reply via email to